Tags: Geyserworx Kit, 300 Litre Geyser Conversion
Geyserworx® 300 Kit - White
Ex VAT
GEYSERWORX® 300 KIT WHITE
*We regret that no shipping is available for this product local pick-up from our offices onlyKIT INCLUDES
Geyserworx® Unit with white acrylic fascia
6 x PV solar panels
2 x 40m PV cabling 6mm
MC4 Connectors
..
Available Options
GEYSERWORX® 300 KIT WHITE
*We regret that no shipping is available for this product local pick-up from our offices only
KIT INCLUDES
- Geyserworx® Unit with white acrylic fascia
- 6 x PV solar panels
- 2 x 40m PV cabling 6mm
- MC4 Connectors
- Thermostat
- AC Wiring for connecting mains
- Wi-Fi remote for smart phone interface to allow for full monitoring and control of geyser
ADDITIONAL PRODUCTS NEEDED
- PV panel mounting brackets
*Once your order is placed we will contact you and request information of your roof type, We will then use 3D software to make sure you order the correct brackets for your installation.
OPTIONAL
- Drip Tray Sensor
INSTALLATION
- Self Installation (Must be compliant please read Compliance below)
- Certified Geyserworx® Installer (We will send you quotations from our list of certified installers in your area)
GEYSERWORX® FEATURES
CONVERTS EXISTING GEYSER TO A SMART SOLAR POWERED GEYSER
INTELLIGENT ELECTRONIC CONTROLLER
MICRO PROCESSOR BASED
CONVERTS PV POWER TO GEYSER POWER
SMART PHONE APP MONITORING & GEYSER SETUP
GEYSERWORX® ADVANTAGES
- Easy and quick installation of the system (+ /- 4 hrs)
- No batteries required
- No loading of the roof and roof trusses
- No moving parts, thus no wear and tear
- No modification of the plumbing
- No glycerin or other heating medium that may contaminate the water
- Use of internet / wireless technologies to manage and set the GeyserWorx® parameters
- 2 year guarantee on Geyserworx® controller
- 20 year OEM guarantee on the components
- Use the existing geyser
GEYSERWORX® OPERATION MODES
Automatic |
Manual |
Timer |
Holiday |
![]() |
![]() |
![]() |
GEYSERWORX® COMPLIANCE
- All wiring must be installed in accordance with all local regulations. (including power and signal cables)
- Power wiring must conform to the local electrical code. Use of a qualified contractor and approval by the local wiring inspector ensures compliance to this code
- Circuit capacity limits are governed by the local regulations. Refer to these, and any other applicable local codes, to determine circuit capacities. Circuits connected to outlets should never exceed 15A load
- The grounding system must be installed in accordance with the SABS Electrical Code, and any other applicable electrical codes. (To include: IEEE-142; Lightning Protection Institute Installation Code LPI-175; NFPA-78 (ANSI);IEEE Std. 142-1972; Code LPI-175)
Unit Technical Specs | |
Operating Voltage | 100V to 280V DC |
Mains Voltage | 220 V AC, 50Hz |
Geyser Element Rating | 1kW, 2kW, 3kW & 4kW |
Geyser Temperature Control Range | 48 ºC to 85 ºC |
Operating Ambient Temperature | -10 ºC to 55 ºC |
Temperature Display Range | 0 ºC - 130 °C |
Earth Leakage Protection at | 25mA action time ≤ 0,1 second |
Heat Failure - When Increase at a Rate of | 2 °C or less per hour |
Dry Heat Detection - Empty Cylinder | Required |
Temperature Tolerance | < 2% |
Temperature Differential Setting | 1°C |
Temperature Probe Failure Detection | Required |
Temperature Probe Range for Geyser | -30 ºC to +130 °C |
Solar Panel Tech Specs | |
Rated Power | 385W |
Length | 1,769 mm |
Width | 1,052 mm |
Depth | 35 mm |
Weight | 20.5kg |
VMPP | 35.04 V |
IMPP | 10.99 A |
Temp. Coefficient (Mpp) | -0.35 % |
Clamp position on panel | Long and short side |
Connector Type | MC4 |
Efficiency | 20.7 % |